Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultramid® A3X2G10 - PA66-GF50 FR(52) - BASF

Material Data Center offers the following functions for Ultramid® A3X2G10:
unit conversion, PDF datasheet print, comparison with other plastics, application examples, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Ultramid A datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informations produit
Glass fibre fibre reinforced injection moulding grade with improved flame retardance. Flame retardant based on red phosphorus; giving outstanding electrical properties and very high stiffness and strength.
Caractéristiques des transformations/physiquessec / condUnitéNorme du test
ISO Data
Indice de fluidité à chaud en volume, MVR 25 / * cm³/10min ISO 1133
Température 275 / * °C -
Charge 5 / * kg -
Propriétés mécaniquessec / condUnitéNorme du test
ISO Data
Module en traction 16000 / 12000 MPa ISO 527
Contrainte à la rupture 180 / 130 MPa ISO 527
Déformation à la rupture 2 / 3 % ISO 527
Module de fluage en traction, 1000h * / 5400 MPa ISO 899-1
Résistance au choc Charpy, +23°C 55 / 55 kJ/m² ISO 179/1eU
Résistance au choc Charpy, -30°C 50 / - kJ/m² ISO 179/1eU
Résistance au choc Charpy (entaillé), +23°C 13 / 16 kJ/m² ISO 179/1eA
Résistance au choc Charpy (entaillé), -30°C 11 / - kJ/m² ISO 179/1eA
Propriétés thermiquessec / condUnitéNorme du test
ISO Data
Température de fusion, 10°C/min 260 / * °C ISO 11357-1/-3
Température de fléchissement s/chrg, 1.80 MPa 250 / * °C ISO 75-1/-2
Température de fléchissement s/chrg, 0.45 MPa 250 / * °C ISO 75-1/-2
Coeffic. de dilatation therm. linéique, parallèle 17 / * E-6/K ISO 11359-1/-2
Coeffic. de dilatation therm. linéique, perpend. 66 / * E-6/K ISO 11359-1/-2
Inflammabilité ep. nom. 1.5 mm V-0 / * class IEC 60695-11-10
Epaisseur de l'éprouvette 1.6 / * mm -
Yellow Card disponible oui / * - -
Inflammabilité pr. épaisseur h V-2 / * class IEC 60695-11-10
Epaisseur de l'éprouvette 0.4 / * mm -
Yellow Card disponible oui / * - -
Inflammabilité 5V pr. épaisseur h 5VA / * class IEC 60695-11-20
Epaisseur de l'éprouvette 1.6 / * mm -
Yellow Card disponible oui / * - -
Aptitude à l'allumage 27 / * % ISO 4589-1/-2
Propriétés électriquessec / condUnitéNorme du test
ISO Data
Permittivité relative, 1MHz 3.6 / 5 - IEC 62631-2-1
Facteur de pertes, 1MHz 200 / - E-4 IEC 62631-2-1
Résistivité transversale 1E13 / 1E10 Ohm*m IEC 62631-3-1
Résistivité superficielle * / 1E13 Ohm IEC 62631-3-2
Rigidité diélectrique 33 / 30 kV/mm IEC 60243-1
Indice de résistance au cheminement - / 600 - IEC 60112
Propriétés diversessec / condUnitéNorme du test
Absorption d'eau 4 / * % Sim. to ISO 62
Absorption d'humidité 0.9 / * % Sim. to ISO 62
Masse volumique 1600 / - kg/m³ ISO 1183
Propriétés spécifiques à la matièresec / condUnitéNorme du test
ISO Data
Indice de viscosité 140 / * cm³/g ISO 307, 1157, 1628
Fonctions
Viscosité / Vitesse de cisaillement , Ultramid® A3X2G10, PA66-GF50 FR(52), BASF
Contrainte de cisaillement / Vit. de cisaillement , Ultramid® A3X2G10, PA66-GF50 FR(52), BASF
Module de cisaillement dynamique / Température , Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Contrainte / Déformation , Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Contrainte / Déformation , Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Module sécant / Déformation , Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Module sécant / Déformation , Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Contrainte / Déformation (isochrone) 23°C, Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Module de fluage / Temps 23°C, Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Courbe de fluage 23°C, Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Contrainte / Déformation (isochrone) 60°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Module de fluage / Temps 60°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Courbe de fluage 60°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Contrainte / Déformation (isochrone) 90°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Module de fluage / Temps 90°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Courbe de fluage 90°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Contrainte / Déformation (isochrone) 120°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Module de fluage / Temps 120°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Courbe de fluage 120°C, Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Volume spécifique (pvT) , Ultramid® A3X2G10, PA66-GF50 FR(52), BASF
Module de traction / Température , Ultramid® A3X2G10 (sec), PA66-GF50 FR(52), BASF
Module de traction / Température , Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Caractéristiques
Transformation
Moulage par injection
Conditionnement
Granulés
Additifs
Agent de démoulage
Propriétés spéciales
Ignifugé, Sans halogène, Stabilisé à la chaleur
Disponibilité régionale
Autres informations
Moulages par injection
PREPROCESSING
Pre/Post-processing, max. allowed water content: .15 %
Pre/Post-processing, Pre-drying, Temperature: 80 - 100 °C
Pre/Post-processing, Pre-drying, Time: 4 h

PROCESSING
injection molding, Melt temperature, range: 290 - 300 °C
injection molding, Melt temperature, recommended: 295 °C
injection molding, Mold temperature, range: 80 - 90 °C
injection molding, Mold temperature, recommended: 85 °C
injection molding, Dwell time, thermoplastics: 10 min
Conditions générales
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.